Factory & Quality

Factory, Quality Control and Testing

Every unit we ship is built to an ABAXEN bill of materials on our own line and released against an ABAXEN test protocol. Nothing leaves the floor without a signed test report.


The Plant

ItemDetail
Manufacturing spaceOver 100,000 m² across six subsidiaries
Employees1,000+
Patents300+
Founded2002
LocationFengxian District, Shanghai
CertificationsISO 9001, ISO 14001, OHSAS 18001

What We Specify

  • Cell supplier and grade — no mixed batches within a pack
  • BMS firmware version and protection thresholds
  • Busbar torque specification and a torque-mark check on every unit
  • Insulation resistance and hipot test limits
  • Communication protocol build and the inverter it is configured for
  • Label content, including serial number format and QR linkage to the test record

Release Tests on Every Unit

TestCriterion
Capacity test≥100% of nameplate at 0.5 C, one full cycle
Insulation resistance≥20 MΩ at 1,000 V DC
Hipot2 × rated voltage + 1,000 V, 60 s, no breakdown
BMS protection verificationOver-voltage, under-voltage, over-current, over-temperature
Communication testFull protocol exchange with the target inverter model
Visual and label auditSerial number, warning labels, torque marks
Burn-in24 h at rated load with monitoring log

Documents That Ship With Every Order

  1. Factory acceptance test report with the serial numbers listed
  2. Wiring diagram and terminal assignment
  3. BMS parameter sheet
  4. Commissioning checklist
  5. Warranty certificate in the buyer’s name
  6. Packing list and UN38.3 transport documents

Request the Audit Report

We share the latest factory audit and the FAT template under NDA.