Off-Grid Power for Farms, Lodges and Islands

No grid, no generator, or a generator you are tired of feeding. Inverter-plus-battery systems from 12 kW to 240 kW, sized on the worst week of the year rather than the average.


The Configuration

ComponentSpecification
InverterINV-G1618, 12 kW, parallel up to 12 units with one comms cable
MPPT2 × 8,000 W per inverter, 500 V DC input
StorageATHENA B/C (15.36–34.3 kWh, 51.2 V) or SCRA-R HV (20–256 kWh, 200–820 V)
Scalability12 inverters in parallel = 144 kW continuous, 288 kW peak
Output230/400 V, 50/60 Hz, pure sine wave
Generator inputAuto start/stop with dry contact

Sizing Rule for Off-Grid

For off-grid systems the battery is sized on the worst week, not the average. Send us daily kWh for the lowest-irradiance month and we will size from that. Oversizing the array and undersizing the battery is the most common and most expensive mistake in off-grid projects — the array produces more than the battery can absorb, and the surplus is thrown away.

Two design rules we apply:

  • Array-to-battery ratio between 1.2 and 1.5 kWp per 10 kWh of storage for temperate latitudes; lower for the tropics
  • Autonomy of 2–3 days on battery alone, with the generator as the third line of defence rather than the second

Typical Projects

ProjectLoadConfiguration
Dairy farm, Kenya18 kW peak, 90 kWh/day4 × INV-G1618 + 3 × ATHENA C (102.9 kWh)
Safari lodge, Tanzania25 kW peak, 140 kWh/day6 × INV-G1618 + SCRA-R HV 160 kWh
Island microgrid, Philippines60 kW peak, 320 kWh/day12 × INV-G1618 + SCRA-R HV 320 kWh + 40 kW genset
Remote clinic, DRC8 kW peak, 35 kWh/day1 × INV-G1618 + 2 × ATHENA B (30.72 kWh)

Project examples are illustrative configurations. Reference contacts available on request under NDA.


Send Us Your Off-Grid Load Profile

Daily kWh for the worst month, peak kW, PV irradiance data if available, and whether a generator will be retained as backup.